Do electric rooflights leak more?
No. A well fitted opening unit is as watertight as a fixed one, and the failure modes are the same.
Part of our Electric and Opening Rooflights guide
No. The waterproofing of an opening rooflight is the same as a fixed one: the covering dressed up the kerb and terminated under the frame, or the flashing kit on a pitched roof. The mechanism sits inside that line.
The reasonable worry

An opening unit has a moving joint with a seal, where a fixed unit has none. That is a real difference and it is engineered for.
The sash closes onto a compression gasket, and on a well made unit the seal is at least as good as a casement window that spends its life in vertical rain.
Where problems actually come from

Debris on the gasket. Leaves, grit and moss on the seal stop the sash compressing properly, and then it does let water past. This is the most common cause and it is maintenance rather than a defect.
Not fully closing. An actuator that stops slightly short, because of an obstruction or a worn mechanism, leaves the sash unseated. It looks shut and it is not.
The same kerb and termination faults that affect any rooflight: too low a kerb, no roof margin, ponding against the upstand.
Cable entry. On a badly detailed installation the cable entry into the frame is a route in. On a properly detailed one it is sealed and enters below the water line.
Maintenance

Wipe the gasket a couple of times a year, particularly under trees, and clear debris from around the frame. That is the whole of it.
Fixed against opening

If ventilation is not needed, a fixed unit is simpler, cheaper and has nothing to maintain. Where ventilation is needed, an opening unit is worth having and the leak risk is not a reason against it.
No, and the reason is worth understanding

A rooflight leaks at the junction between the unit and the roof, not at the mechanism. The flashing kit, the underlay collar and the sequence in which the covering is reinstated are what keep water out, and those are identical whether the window is manual, motorised or fixed.
A motorised unit has more parts, but the parts it has are inside the frame, on the warm side, and they play no role in weathering the opening.
Where the perception comes from

Three things, and only one of them is really about the motor.
Opening units are less watertight than fixed ones, which is true and applies equally to manual openers. Any window that opens relies on a compression gasket rather than a permanent seal, and a gasket is a maintained component.
A dirty gasket stops the sash seating. This is the real cause of most water reported at an opening rooflight. Grit, leaves and moss on the compression seal hold the sash a fraction open, water gets past, and it is reported as a leak.
On a motorised unit it is slightly more likely to go unnoticed, because a motor will close the sash against an obstruction where a person closing it by hand would feel the resistance.
A stuck rain sensor. A dirty sensor can misread, and a window left open in rain will let water in. That is a maintenance issue rather than a leak.
What actually prevents it

Clean the gasket once a year. It is the single most useful thing you can do to any opening rooflight, and it takes minutes.
Wipe the rain sensor at the same time, because a sensor caked in grime either misses rain or reads permanent moisture and refuses to let the window open at all, which looks exactly like a fault.
Cycle the unit fully a few times a year so the mechanism does not seize and the sash keeps closing squarely.
The genuine advantage

A rain sensing motorised unit is less likely to let water in than a manual one, because it closes itself when it starts raining. A manual window left open on a summer morning stays open through the afternoon shower.
That is the practical answer to the question: over a year, a motorised rooflight with a rain sensor admits less water than a manual one, not more.
What we specify
A rain sensor as standard on any motorised unit rather than as an option, and the same flashing, underlay collar and insulation collar detail as on any other rooflight. The weathering does not change because the window has a motor in it.
Not inherently, but there is more to go wrong
A fixed rooflight has a bonded edge that never moves. A powered one has a sash that opens, which means a compression gasket doing real work every cycle, and a moving joint is always a harder sealing problem than a static one.
So the honest answer is that a powered unit has one more component in the weathering chain, and that component is a wear item.
What actually causes water ingress on a powered unit
A dirty or obstructed gasket. Debris sitting on the sill means the sash cannot close evenly against the seal. This is the commonest cause and it is prevented by a wipe once a year.
A perished gasket. Rubber ages, and after fifteen or twenty years it hardens and stops recovering after compression.
A unit left open in rain. Not a defect. A rain sensor prevents it.
A blocked drainage channel. Powered units have drainage paths designed to take water that gets past the outer seal back out. Blocked, they back up.
What is usually not the cause
The motor or the electrics. Actuators are housed in the frame and do not create a water path.
And the cable entry, on a properly installed unit, is a designed penetration rather than a hole somebody made.
The practical conclusion
A powered rooflight is as reliable as a fixed one if the gasket and drainage are kept clear. That is a five minute annual task.
Where a unit is genuinely inaccessible and will never be maintained, a fixed rooflight with ventilation provided elsewhere is the more robust choice.
More on Electric and Opening Rooflights