Do rooflights meet current building regulations?
Any decent modern unit does, comfortably. The kerb and the installation are where compliance is actually lost.
Part of our Energy Efficient Rooflights guide
The unit itself, comfortably. The requirement for a replacement in an existing dwelling is a whole unit U-value no worse than 2.2, and a modern double glazed rooflight lands around 1.2 to 1.4.
Which parts apply

Part L, conservation of fuel and power: the U-value, and on extensions the total glazed area as a proportion of floor area.
Part K, protection from falling and impact: safety glazing overhead, which is why a laminated inner pane is standard.
Part B, fire safety: relevant where a rooflight is a means of escape, and where it penetrates a fire resisting ceiling.
Part F, ventilation: where the rooflight forms part of how a room is ventilated.
Part A, structure: the opening and its trimming.
Where compliance is actually lost

Not the unit. Three other places.
The structure, where an opening is inadequately trimmed or a truss is cut without a design.
Thermal bridging, where the kerb is uninsulated. The regulations expect continuity of insulation, and an uninsulated upstand does not provide it.
Notification, where notifiable work was never notified. The installation may be perfect and there is no certificate to show for it.
Whole unit, not centre pane

The regulation uses the whole unit figure. Marketing often quotes centre pane, which is always better. Compare like with like.
Who notifies

Where notifiable, we handle it and the certificate comes to you. It is the document a buyer’s solicitor asks for.
Any modern unit clears the standard comfortably

For a replacement rooflight in an existing dwelling, Part L expects a whole unit U-value no worse than 2.2. A current double glazed unit with a low emissivity coating, argon fill and a warm edge spacer lands around 1.2 to 1.4.
So the answer is yes, with a wide margin, and it is why the requirement rarely causes anybody trouble.
Watch which number you are given

Two figures describe the same product and only one of them is the regulated one.
Centre pane U-value measures the glass away from the edges and ignores the spacer and the frame, which is exactly where heat escapes. It is always the better figure and it is what marketing quotes.
Whole unit includes glass, spacer and frame weighted by area. It is what the building experiences and what Building Regulations use. It is always worse, frequently by 0.4 or more, and on a small unit with a lot of frame relative to glass the gap is wider still.
A rooflight advertised at 1.0 and another at 1.4 may well be the same performance described two ways.
Where it actually bites

Not on a replacement. On an extension.
The rooflights form part of the thermal calculation for the whole structure, so a poor unit forces better performance somewhere else in the build. There is also a limit on total glazed area as a proportion of floor area, which means a heavily glazed extension needs a calculation rather than an assumption.
Getting the glass right first is cheaper than compensating for it in the walls afterwards.
The other parts that apply

Part A, structure. Where an opening is formed or widened. In a trussed rafter roof, cutting any truss member needs a designed trimmer and an engineer.
Part B, fire safety. In a habitable loft room a roof window frequently carries the means of escape duty, which brings a minimum clear openable area, minimum opening dimensions and a maximum sill height above the floor.
Part F, ventilation. An opening rooflight contributes to purge ventilation. The free area varies by model and opening type, so a top hung unit and a centre pivot of the same size are not equivalent.
Part O, overheating. Applies to new dwellings rather than extensions of existing houses. Where it does apply, the simplified route limits glazing area by orientation and a design with a lot of south or west facing rooflights can fail it regardless of how good the glass is.
What is not covered by a product certificate
The installation. A manufacturer’s certificate shows the unit meets the standard. It says nothing about whether the flashing kit was the right profile, whether the underlay collar was lapped correctly, or whether the insulation collar was fitted.
Those decide whether the installation performs as the certificate suggests, and they are invisible once the job is finished.
How to check what you are being offered
Ask for the whole unit U-value in writing, on the quotation, alongside the model and size. A supplier who gives you a centre pane figure and calls it the U-value is not necessarily being dishonest, but you cannot compare two quotations on it.
Then ask whether the insulation collar, or on a flat roof the kerb insulation, is included. That is where the performance actually goes.
Ask us
Send the quotation you have been given and we will tell you honestly whether the figures on it are comparable with ours. Centre pane and whole unit are frequently used interchangeably and they are not the same thing.
What a product certificate does not cover
The installation. A manufacturer’s certificate shows the unit meets the standard. It says nothing about whether the flashing kit was the correct profile, whether the underlay collar was lapped properly, or whether the insulation collar was fitted, and those decide whether the installation performs as the certificate suggests.
One last point
The requirement bites on extensions rather than replacements. On a replacement any modern unit clears it comfortably; on an extension the rooflights form part of the calculation for the whole structure.